1. FIELD SIZE:
The playing field is a rectangle of dimensions between the following limits:
FIELD DIMENSIONS |
Length (band lines) (m) |
Width (target lines) (m) |
Maximum | 42 | 25 |
Minimum | 25 | 16 |
In international
competitions the dimensions will be:
FIELD DIMENSIONS (International competitions) |
Length (band lines) (m) |
Width (target lines) (m) |
Maximum | 42 | 25 |
Minimum | 38 | 20 |
In any case the length of the band lines must be higher than the length of the lines meta.En professional
high level football, as well as in national and international significant matches, the dimensions of the field of play are 40 m in length and 20 m in
total
anchura.En facilities
where the room football runway is also for sports use is useful and it is recommended that the dimensions of the field be 40 m in length and 20 m
FIELD DIMENSIONS (Total blind) |
Length (m) |
Width (m) |
Maximum | 42 | 22 |
Minimum | 38 | 18 |
Its
length will always be longer than the anchura.En international
competitions the indoor soccer field for the total blind (B1) will have dimensions of 40 m x 20 m.El indoor
soccer field for the visually impaired (B2 and B3) is a rectangle of dimensions between the limits indicated in point 1.2. OUTER BANDS AND SECURITY TO FACILITATE THE DEVELOPMENT, THE VISION OF THE GAME AND FOR SAFETY,
an obstacle free safety band
of at least 1 m wide outside the bandwidth lines and 2 m wide behind the finish lines shall be available around the playing field. Its color can be contrasted with that of the playing field. The playing field must be separated from the public areas, if they exist, and in such a way that it does not pose a risk of injury to gamers.3. PLOTTING OF THE CAMPOEhe plotted of the soccer field room will be made according to the figures
All brands lines shall be 8 cm wide and shall be of a colour that is perfectly distinguishable from the playing area. All lines belong to the surface of the delimited area. For mini-futsroom, schoolchildren undergoing initiation and categories benjamín and alevín (ages between 6 and 11 years), will be done according to the figure
3.1 FIELD LAYOUT FOR TOTAL BLIND (B1) AND VISUALLY IMPAIRED (B2 and B3)The
layout of the futsal playing field for the total blind (B1) shall be according to the figure
The sidelines of the band are configured by fences along the playing field, plus 1 m outward to avoid the off-band. The fences shall have a height of 1,00 m to 1,20 m and a maximum inclination of 10° towards the outside of the field. For the safety of the players, the side fences shall not have live edges, the edges shall be rounded with a radius of at least 4±1 mm and shall not have gaps greater than 8 mm which may cause finger trapping, the surface shall be of flexible material or shall have padded damping protections, the surface of the padded protections shall be of a sturdy material and must be fixed to the side fences. See figure
The layout of the indoor football field for the visually impaired (B2 and B3) is the same as shown in the figures.
4. OBSTACLES FREE HEIGHT BETWEEN
THE SURFACE OF THE SPORTS PAVEMENT AND THE NEAREST OBSTACLE IN INDOOR INSTALLATIONS (LOWER SIDE OF THE ROOF, BEAM HANGER, LUMINAIRE, AIR CONDITIONING DUCT, etc.) and in outdoor facilities it shall be at least 7 m above the field and the outside bands, leaving at that height totally unobstructed. In high-level competitions it is recommended that the free height be at least 10 m.En competitions of the Real Federación Española de Fútbol and of the Liga Nacional
de Fútbol Sala the matches will be held in pavilions cubiertos.El playing field of futbol sala para ciegos total (B1) will be discovered, in
order to avoid the inadequate reverberation of large number of the cliffs prevent competition, a field covered by the same characteristics shall be available in order to ensure continuity of competition. The acoustics of these covered fields shall comply with the acoustic requirements of the NIDE Salas and Paviones.5. ORIENTATION SOLAREthe longitudinal axis of the runway, in outdoor facilities, must coincide with the geographical direction N-S, allowing a variation between N-NE and N-NO.6. LIGHTING WILL BE UNIFORM AND WILL NOT CAUSE GLARE TO PLAYERS. In live soccer competitions for the visually impaired (B2 and B3), it must be protected from possible reflections
of sunlight or artificial light that could occur in the playing area and that could alter or limit the development of the game as the movement of the players. Artificial lighting shall be uniform and so as not to cause glare to the players, the arbitral team or the spectators. It shall have the following minimum levels of horizontal lighting and colour performance, in accordance with the criteria
of UNE-EN 12193 “Lighting
of sports facilities”, as indicated below:
MINIMUM LEVELS OF INDOOR SOCCER LIGHTING (Interior) |
|||
COMPETITION LEVEL | Horizontal illuminance |
Rend. Colour (Ra) |
|
E (lux) |
Uniformity E min/ E med |
||
International and national competitions | 750 | 0.7 | 60 |
Regional and local competitions, high-level training | 500 | 0.7 | 60 |
Training, school and recreational sport | 200 | 0.5 | 20 |
The following minimum lighting and maximum glare levels (GR), as indicated in the above standard, shall be available
on external runways:
MINIMUM LEVELS OF INDOOR SOCCER LIGHTING (Outside) |
||||
COMPETITION LEVEL | Horizontal illuminance |
Rend. Colour (Ra) |
GR £ |
|
E (lux) |
Uniformity E min/ E med |
|||
International and national competitions | 500 | 0.7 | 60 | 50 |
Regional and local competitions, high-level training | 200 | 0.6 | 60 | 50 |
Training, school and recreational sport | 75 | 0.5 | 20 | 55 |
In order to broadcast TV color and film recording, a level of vertical illuminance is required depending on the speed of the action and the dimension of the object, in the aforementioned standard UNE-EN 12193, sports have been classified, in this sense, into three groups A, B and C; the ballroom football belongs to group B. The value of the vertical illuminance varies with the distance from the camera to the object.
Level of vertical illumination to be maintained according to the maximum shooting distance of the cameras (UNE-EN 12193)For TV
shots or movies, the spaces surrounding the handball track must be illuminated, so that the level of vertical illumination is at least 0,25 of the level of vertical illumination of the gaming track. For further information the standard citada.Para must be consulted the competitions of the National League of Futbol Sala, the following
is required:- Minimum lighting level of 1,200 lux.- In televised competitions the recommended
minimum lighting level of 1,700 lux, without prejudice
to the required by the technicians in terms of power, luminosity, orientation, etc.En the same indoor football competition for visual deficiencies. SPORT FLOORING suitable for wooden or synthetic flooring, fixed or detachable. Rigid pavements are not recommended. For competitions of the 1st Division of the Liga Nacional de Fútbol Sala, the sports pavement will be
wooden. Exceptionally, artificial grass surfaces are allowed only for competitions nacionales.En competitions for the total blind (B1) of the Spanish Federation of Sports for the Blind the playing area can be of wood, synthetic grass or synthetic pavements, the
following surfaces are
not recommended for the surfaces of concrete or tar n.El sports pavement will include the surface of the field of play and the exterior sports bands Specifications for indoor multisport floors”:
REQUIREMENTS INDOOR SPORTS AREA FOR INDOOR FOOTBALL |
||
Strength reduction* (Absorption impacts) |
RF³45% RF³35% RF³25% |
Competitions and come in. high national level Regional competitions and training Local, recreational, school competitions |
Vertical deformation** |
£ 3.5mm £ 3mm £ 2mm |
Competitions and come in. high national level Regional competitions and training Local, recreational, school competitions |
Sliding | 80 - 110 | |
Vertical Balloon Boat | Altura 1º bote vertical: ≥ 50 cm y ≤ 65 cm, altura de caída 2,00 m. | |
Impact resistance | No cracks, cracks or deformations greater than 0.5 mm for 8Nm impacts | |
Fingerprint resistance | No cracks, cracks or deformations greater than 0.5 mm at 24 h. | |
Rolling stock*** | No cracks, cracks or deformations greater than 0,5 mm for a minimum load of 1500 N | |
Abrasion resistance |
Synthetic surfaces: Maximum weight loss 1,000 mg (1000 cycles, wheels H-18, load 1.0 kg) |
|
Coatings and lacquers: Maximum weight loss 80 mg (1000 cycles, wheels CS-10, load 0,5 kg) |
||
Specular reflectance | For an angle of 85º, the value obtained shall be recorded. | |
Specular gloss |
For an incidence angle of 85º: ≤ 30% Matte surfaces; ≤ 45% Lacquered surfaces |
|
Formaldehyde emission | Products made with formaldehyde must be tested and belong to class: E1 or E2 | |
Pentachlorophenol (PCP) content | Sports surfaces must not contain it as a component of the product or its raw materials | |
Reaction to fire | Must be tested and classified according to UNE-EN 13501-1 declaring Class and Subclass resulting from fire behavior | |
Planness/ Surface Regularity (“in situ”) |
£ 6 mm with 3 m rule; £ 2 mm with 0.3 m rule |
* Wood soils (Areaelastics): RF≥55% in high level; RF≥40% other levels. ** Wooden floors
(Areaelastics): Def. vertical ≥ 2.3 and < 5 at high level; Def. vertical ≥ 1,8 and < 3,5 other niveles.Suelos wood + synthetic
(Combined deformation): Def. vertical ≥ 1.8 and < 5 for high level *** If the surface is
to be covered by telescopic stands or rolling equipment pesado.Los outdoor sports paving
shall comply with the following requirements:
Evacuation earrings | Cross-sectional and maximum 1% |
Planness / Surface Regularity (“in situ”) UNE-EN 13036-4 |
£ 6 mm with 3 m rule; £ 2 mm with 0.3 m rule |
Vertical Balloon Boat UNE-EN 12235 |
Altura 1º rebote vertical: ≥ 50 cm; ≤ 65 cm, altura de caída 2,00 m. |
Strength reduction (synthetic) UNE-EN 14808 |
RF³25% |
Vertical deformation (synthetic) UNE-EN 14809 |
£ 6mm |
Slip (synthetic) UNE-EN 13036-4 |
55 - 110 |
Tensile strength (synthetic) UNE-EN 12230 |
³ 0.40 MPa |
Lengthening of breakage (synthetic) UNE-EN 12230 |
³ 40 % |
When using synthetic grass sports pavements, they shall comply with the following general and specific requirements based on the standard UNE-EN 15330-1:2007 “Surfaces for sports. Specifications for synthetic grass”:
GENERAL REQUIREMENTS SPORTS AREA OF SYNTHETIC GRASS |
||
Colour
|
When tested according to the method EN 20105-A02, after artificial aging according to UNE-EN 14836, the color change of the synthetic grass compared to the non-aged will be 4 on the gray scale or higher | |
Traction | When tested according to the UNE-EN13864 method, after artificial aging according to UNE-EN 14836, the tensile strength of the threads used to form the synthetic grass shall be at least 50% compared to the non-aged | |
Water permeability (UNE-EN 12616) |
Infiltration rate ≥ 180 mm/h (Surfaces designed to be permeable) | |
Resistance of joints (UNE-EN 12228) |
Sewn joints |
After immersion in hot water according to UNE-EN 13744, the strength of the sewn joints shall be at least 1000N/100 mm |
Glued joints | After immersion in hot water according to UNE-EN 13744, the resistance of the attached joints shall be at least 25 N/100 mm, | |
Abrasion resistance / wear of unfilled synthetic grass (%) (UNE-EN 13672) |
Maximum percentage lost mass 2% (2000 cycles) |
SPECIFIC SPORTS AREA REQUIREMENTS SYNTHETIC GRASS FOR INDOOR FOOTBALL |
||
Reduction of force (Absorption impacts) |
RF40% | |
Vertical deformation |
4 – 10 mm (Dry or wet conditions) |
|
Vertical Balloon Boat |
Height 1 vertical boat: ³ 50 cm and ≤ 65 cm, drop height 2,00 m. |
|
Slip resistance | 55 - 110 | |
Evacuation earrings (Outdoor fields) |
Cross-sectional and maximum 1% | |
Ball rolling |
≥ 4 m; ≤ 10 m (Dry or wet conditions) |
|
Resistance to use | After 5,200 cycles, impact absorption and vertical balloon boat values must be maintained. | |
Planness / Surface Regularity (“in situ”) |
£ 6 mm with 3 m rule; £ 2 mm with 0.3 m rule |
The manufacturer and the installer of the sports pavement shall provide the documentation of the sports pavement which shall include at least the following:-
Results of the laboratory test of a pavement sample.-
Description of the installation procedure.- Information on
the maintenance of the sports pavement.- The results of
the “on-site” tests and their compliance with the required requirements.8. THE GOAL OR PORTERIAEthe soccer field will
be equipped with two goals
or lotteries. They are placed at the center of each finish line. Its interior measurements are 2 m high by 3 m wide
They shall comply with the rules of the Football Game Rules and the safety requirements of the standard UNE-EN 749.Las
for lotteries shall comply in particular with the resistance and stability requirements required by the UNE-EN 749 standard mentioned above. The racks must be stable and have an anti-roll system by clamping to the ground by means of an anchor system or to the walls behind them, so that, although the system prevents its overturning, it allows a slight horizontal movement of the same that reduces a player's strike against the frame in case of impact. See figure
The goal consists of frame, network and clamping elements of the red.En indoor soccer
competitions for the total blind (B1) and for the visually impaired (B2 and B3) the goal will have the characteristics described above, besides for the visually impaired (B2 and B3) there will be contrast between the goal and the bottom for a better perception of it by the players. The lotteries, even if they have an anti-roll system, cannot be fixed to the ground to safeguard the physical integrity of the players, and avoid injuries in case of shock against
ellas.En competitions of minors under 16 years of age, female teams, veteran players over 35 years of age and players with disabilities, different internal measures of the goal or meta.En
mini football room, the porcupboards may have internal measures Dimensions of length 2.70 m and height 1.60 m and 1.80 m can also be used. For novice children, smaller portions (2.20 m x 1.50 m) can be used. See figure
8.1 THE MARCOEl
frame is composed of two posts and the crossbody or wire, built of the same material (wood, steel, light alloy or plastic material) not corrosive or protected from corrosion. It shall be of square, rectangular, or elliptical section, 8 cm wide and painted faces with colors which clearly contrast with the bottom of the playing field, as indicated in the figure DOCS-4. The edges or edges shall be rounded with a radius of at least 4±1 mm.8.2 THE REDDe square mesh, may be
made with yarns of
natural fibres (hemp, jute) or synthetic fibres (nylon), the diameter of the yarn shall be at least 2 mm, the width of the mesh shall be at most 10 cm. The network must be subject to the poles and the large, at least every 20 cm.8.3
THE ELEMENTS OF THE NETWORK
MUST be fixed to the poles and large without being tense to prevent the ball penetrating it from bouncing to the outside and in such a way that it cannot pass through it or hold a hole between it and the poles (4). No steel hooks abiertos.Cuando will be used for the network the rear supports will not stand out from the frame of the porteria.El clamping system will be such that a ball that enters the goal cannot bounce off the constituent parts of it. 9. THE BALOS shall consist of a
leather or synthetic cover, its outer surface shall not be glossy or slippery. It will have a circumference between 62 cm and 64 cm and a mass between 400 g and 440 g at the beginning of partido.Tendr at a
pressure equivalent to 0.6-0.9 atmospheres (600-900 g/cm²) at the marThe balloon boat dropping from 2 m height will reach a
height between 50 and 65 cm in the first boat. See figure
In competitions of children under 16 years old, female teams, veteran players over 35 years old and players with disabilities, modifications in the size, weight and material of the bucket n.En
categories Pre-Benjamin, Benjamin and Alevín the ball will be 58 cm. circumference and 368 g mass. The ball will have the same characteristics (B2
and B3) and its color will contravene vividly with that of the sports pavement, may be white, green, orange or of any color that assists its location n.En soccer
competitions for the total blind (B1) the ball will be sonorous, with an internal sound production system that does not The balls shall have the official logo indicating that it has been officially checked and that it complies with the technical specifications for each logo, in addition to those indicated above. There are three official designations: “FIFA APPROVED” Approved by FIFA• “FIFA INSPECTED” Inspected by FIFA• “IMS INTERNATIONAL MATCHBALL STANDARD” International Standard Ball (not licensed)Two levels of criteria are set for the three official designations, the requirements for the category “FIFA INSPECTED” or “TOP”. The technical requirements are as follows:
FIFA QUALITY TEST REQUIREMENTS FUTSAL BALLS |
|||
Test | “APPROVED” |
“INSPECTED” “IMS” |
Specifications |
Weight | 410 - 430 grams | 400 - 440 grams | ball pressure: 0.6 bar |
Circumference | 62.5 – 63.5 cm | 62.0 – 64.0 cm | ball pressure: 0.6 bar |
Sphericity | maximum 1,5 % | maximum 1,8 % | ball pressure: 0.6 bar |
Pressure loss | maximum 20 % | maximum 25 % |
ball pressure: 0.6 bar maximum air loss after 72 hours |
Rebound | 55 - 65 cm | 50 - 65 cm | ball pressure: 0,6 bar Ball falling from a height of 2 m on a wooden floor |
Balance | 5th maximum | 7,5º maximum |
ball pressure: 0.6 bar The deviation angle of the tread direction of a ball is measured, which is allowed to be rolled over a sloped slope on a board with a predetermined tread direction. |
Form and size retention test including change of pressure:
·Increased circumference ·Deviation from sphericity ·Change of pressure |
Measured after 2,000 shots, seams and air valve without damage
max. 1.0 cm
maximum 1.5%
maximum 0.1 bar
|
ball pressure: 0.6 bar Disparo a una lámina de acero a 50 km/h aproximadamente, distancia de disparo: 2.50 m |
The tests will be performed at room temperature (approx. 20° C) and with
65% humidity. SAFETY NETS IN ORDER TO STOP BALLS NETS
WILL BE PLACED BEHIND FINISH LINES, NETS WILL HAVE MESH WIDTH AT LEAST THAT THE HOIST NETWORK WILL BE SUSPENDED THROUGHOUT THE FIELD AND SAFETY BANDS WILL BE BE BLACK HIGH SCOREBOARD AND CRONOMETROEl scoreboard will be placed in perfect visibility for the scoreboard, for players and the public. The scoreboard and timestamp shall indicate the time of play and also record valid goals according to the origin n.En of national competitions, at least one scoreboard and electronic chronometer shall be available, so that it can be operated from the scoreboard. It will be placed at a height and in a position that can be seen correctly by players and spectators. You will have electronic timing showing the time played, the goals, cumulative shortages and the periods of juego.En the
competitions of the Real Federación Española de Fútbol will be available an electronic marker that will reflect: period and time of game, tanteo, number of cumulative shortages of each team, acoustic signal for the interruptions
of the game and
warnings, which has sufficient intensity and is visible table sign MEGAFONÍAEn sports facilities where high-level national competitions are to be held, the sports facility must have a public address system. The public address system must allow
individual control of the sound system in the areas where media representatives are located and comentaristas.El the public address system must be designed to automatically make warnings in case of emergency, both athletes and espectadores.En the competitions of the National League of Football Sala are required to provide the public address room with a power of at least 500 total espectadores.En. CLOSED CIRCUIT OF TELEVISION (CCTV)In sports facilities where high-level national competitions are to be held, the sports facility must have a closed circuit of colour television for watching the spectators, if required by the authorities for the prevention of violence in sport, but it is advisable to foresee its
installation. The CCTV installation will have fixed and mobile cameras that control the interior and exterior (graderío, accesses, etc.). ), own supply of electricity and will be operated from the organisational control room of the installation. 14. ORGANISATIONAL CONTROL UNIT (UCO) In sports facilities where high-level national competitions are to be held, if required by the authorities for the prevention of violence in sport,
due to the importance of the competition, the number of attendees, the safety of it and the modality of its development, a control room will be available from which you have an overview of the installation (runway, grades, etc. ), the organisational control unit shall have at least a closed-circuit television, public address and radio and telecommunication links, as well as any other means necessary for the control of the restaurant.15. USEFUL SPACES TO THE ATHLETES
high level
competitions, in addition to the central runway of the sports facility, there must be two rooms for heating and training before the game, with an area of at least 50m2. The walls of these rooms shall be smooth, without projections, and covered with cushioning material if there is a risk of the athletes' impacts with them, the ceiling and the luminaires shall be protected from the impacts of the ball with a
non-stressed net. They shall be ventilated and heated or heated to maintain a temperature between
18ºC and 24ºCC.El. They shall have ventilation and heating or air conditioning and shall comply with the requirements indicated in the NIDE standard “Salas y
Paviones” Sports Spaces, Piste Polideportivo. In sports facilities for high-level competitions, a temperature will be maintained between 18ºC and 24ºC.15.1 SPACES FOR THE SCORER TABLE AND TECHNICAL AREA. AUXILIARY AREA Externally to the safety band, there will be on one side
of the track
a space for the scorer table and another for the technical area, with a width at least 1 m and recommended 1.50 m, see figure
The technical area is the special area for the technical staff and the players reserves of each equipment, the technical area extends in 1 m on each side of the equipment seat bench and forward up to 75 cm of the band line in front of the replacement area. Alternate and technical footballers shall be located on one side of the field, on both sides of the scoreboard and at a distance of at least 5 m from the half-field line. See figures
In national sports competitions, the scoreboard table shall be equipped for electronic monitoring of the meetings (internet connection, telephone line and electrical outlets).In
competitions where spectators are available close to the technical area and the safety scoreboard it is advisable to have transparent protection for the bancos.En
sports facilities where high level sports competitions are to be held, an auxiliary area shall be available around the safety table and The protected area, gaming track, security bands and outer perimeter space shall not be accessible or accessible to viewers. See figure
In competitions of the Real Federación Española de Fútbol the banquillos must be at a minimum distance of 2 m from the pú separation fence blico.En
competitions of the Liga Nacional de Fútbol Sala a minimum security zone of 2 m, without public, around the banquilles and protected by security service or protection of both banquilles by means of a rigid and transparent system with the side protected. Likewise, the public must be located at a distance of at least 2 m from the side and bottom lines of the field of play and 3 m from the protections of the banquillos.En competitions of the Real Federación Española de Fútbol
must have a step intended exclusively for the entry and exit of footballers, referees, chronometers, coaches, auxiliaries or any other authorized person, arranged in a public space Thus, being the playing field in these competitions of 40 m by 20 m (see point 1), the total area to be predicted for playing field, safety bands and auxiliary area shall be 50 m in length and 35 m wide. AUXILIARY SPACES FOR ATHLETES 16.1 COSTUMES, ATHLETE TOILETS, COACHES will have at least two separate costumes, one for each team. Changing areas of clothing with benches and hangers, area of showers with drying space and area of
toilets with toilets and washbasins shall be available in the changing rooms. The characteristics of these spaces are detailed in the NIDE standard “Rooms and Pavilions”.For high-level sports competitions, four costumes are required for the players of the planned meeting and the next meeting, if the times of these meetings are very close. The changing rooms shall be located as close as possible to the game track, on the side of the change zone and with protected direct access to it, shall not be accessible to viewers or the media. The locker rooms shall have a minimum area of 65 m2 and shall consist of areas with the following characteristics:• Changing area
of the players' clothing, equipped with
benches, hangers or closets, slate. Recommended
minimum area of 35 m2.• Massage area with at least two massage beds, ice machine and refrigerator.• Area of showers, with non-slip and waterproof floor, with a minimum of 6 showers and recommended of 10 showers. • Toilet area (2 minimum, 3 recommended), urinals (2 minimum, 3 recommended), washbasins with mirrors (2 minimum, 4 recommended), hair dryers (2 minimum, 4 recommended) and pool for
the pies.Se will have a room of coaches adjacent to each of the equipment locker rooms, with bench, hangers or cupboards wardrobe, sink, toilet, toilet. MINIMUM AREA 15 m2In competitions of the Spanish Football Federation and the National League of Football Sala, adequate and independent costumes will be available for each team with minimum capacity for 15 people, with toilets, showers and washbasins with hot and cold water a.Por security reasons may be necessary the installation of a protective tunnel with regard to the graderío of spectators, which may
be extended These locker rooms shall have a changing area of clothing with benches and hangers, a shower area with drying space and an toilets area with toilets
and washbasins. In the same locker room or annex there will be
an area for writing records, reports, etc. with the appropriate furniture. Also the characteristics of these spaces are detailed in the NIDE standard “Salas y Paviones”.
In competitions of the Real Federación Española de Fútbol and of the Liga Nacional de Fútbol Sala, the sports facility will have a costume for referees, provided for a number of four people, with showers and washbasins with hot and cold water, toilets, meetings, etc. They will have an area of toilets with toilet and washbasin .16.4 RECOGEBALL WARDROBE international competitions, where required, two separate dressing rooms must be provided for boys and girls recogebalones.16.5 NURSING – FIRST AID and will have in place so that access to it from the track is easy and will
have a quick exit to the sick vehicles or emergency evacuations. The spaces and doors shall have sufficient width for the passage of beds, the corridors shall be at least 2,25 m
wide and the doors shall be 2,20 m wide. It shall be equipped with an examination table, stretcher, a desk table, armchair, a cabinet cabinet, clothes rack and medical equipment essential for first aid. The first aid room must
be available for both athletes and the public if there is no other specific for the partyblico.En high-level sports competitions, a separate first aid room may be required for players
and another for the public. The first aid room for players will be arranged in such a way that it can be reached directly and quickly by the emergency services from the outside as well as from the game track itself. It will be located at the level of the runway with easy and quick exit to the outside, the accesses will be free of obstacles, so the injured player can be moved there quickly. The first aid room for the public will allow the first
aid to be administered to
the public in need. It must be easily accessible from the graderío and from ambulances abroad via reserved routes. Both rooms will include a toilet and a sink preferably with an anteroom that allows direct access from the first aid room. They must be equipped with 2 stretchers with separator element between them, table, armchair and cabinet duly equipped with first-aid material. 16.6 CONTROL ROOM OF DOPAJEEn official competitions a doping control room will be available, which will have exclusive use for this purpose. It must
comply with the requirements laid down in Order PRE/1832/2011 of 29 June regulating the doping control area, the sampling material and the protocol for handling and transporting blood samples and will have the following spaces:• A waiting room with chairs and refrigerators for non-alcoholic beverages or other substances that could give rise to adverse results, and adjacent room/s for collection of blood containers If
it is an
additional room, refrigerators shall be fitted with a wrench to store the samples to their traslado.Para high-level competitions, the doping control area shall have a minimum surface area of 30 m2 and shall include:• Waiting room with seats for 8 people with hangers
or
cupboards and refrigerator.• Working room with table and four chairs, wardrobe with wrench and sink. It will
have easy or direct access
to the sports track and from the outside of the sports facility without obstacles, it will meet the requirements of the NIDE standard “Halls and Pavilions”.17. NATURAL AUXILIARY AREAS17.1 OFFICES OF ADMINISTRATION AND ACCREDITATION ROOM ON SPACES INTENDED FOR PERSONS RESPONSIBLE FOR THE ADMINISTRATIVE MANAGEMENT OF THE SPORTS FACILITY. Its size will be according to the size of the sports facility it serves, however it is recommended that each area has a space of not less than 20 square meters. It shall meet the requirements of the NIDE standard “Rooms and Pavilions”. For high-level international competitions, offices with the necessary surface area and equipment will be available for the planned events. It is recommended
to have the following spaces:• Two work rooms and offices.• Work room for delegates.• Meeting room for 15 persons.• Two warehouses for temporary storage of sports equipment, technical equipment. )• Space for accreditation in the entrance lobby, with direct access from the outside and area of 30 to 50 m2. Vips and media accreditation spaces shall be differentiated and separated from the rest. All the accreditation spaces will be clearly signalled17.2 PERSONALLthe staff rooms will be of a size depending on the number of people involved in the preparation of the game track, cleaning, maintenance of technical facilities, etc. These costumes will be arranged separately from the area of sportspeople and referees' costumes.17.3 SPACES FOR AUTHORITIES AND PERSONALIDADESEhe large sports facilities will be provided a reception area and a stay of authorities and personalities, which will be located near the Tribune of authorities as a prepalco. For high-level competitions, it is necessary to reserve spaces to receive VIP guests in an efficient and functional way, whose dimension depends on the type of event. It is recommended to have a hospitality vip room suitable for at least 100 people, with an area of 100 m2. These spaces will also be available for use in the event fines.As for parking spaces for at least 50 vehicles with a separate area of access and direct access to the interior of the facility and close to the Hospitality Room.17.4 SPACES FOR THE MEDIA OF COMMUNICATION The distance to the press centre must be short.- Radio and TV commentators:• Fixed booths with a space of 3 m x 3 m each, with a window of possible opening in the front of the booths, acoustically insulated, with good visibility and without obstacles to the game track. At least 6 spaces with two seats each will be available.• Each commenter will have a desk large enough to place their equipment (TV screen, PC, fax, working papers, etc.) and will have electrical outlets, internet connection, printer, etc.• The commenter area will be easily accessible from other working
areas and will be located in
the central gallery next to the main fixed cameras, separate from the public. Commentators will have an unobstructed field view.- TV cameras:• The main cameras are usually located on the side of the judges’ table and substitution area, close to the axis that marks the midfield line, placed in an elevated position. In addition, other cameras are available, two on each corner of the playing field and two on top of the lotteries ensuring that
they do not obstruct the viewers’ vision.• Other fixed or mobile cameras are placed in positions different to the level of the playing field or slightly elevated, ensuring that they do not obstruct the viewers’ vision.
The number of cameras and their situation will be agreed with the organizer and the TV company, prior to the event.• The platform for each camera will be approximately 2 x 2 m.• If there are windows in
front of the main cameras, they must be darkened to avoid the risk of dazzling.• In any case the planning must be coordinated with competent media experts TV.En
National League of Meetings competitions if requested.- Press Conference Room and Press Working Room: A press conference room, equipped with microphones and a public address system, electricity sockets and sufficient furniture for a minimum number of 60 people and space for TV cameras, will be available. In addition, it
is necessary to provide a working room for the press, equipped for a minimum of 50 jobs, with the
facilities, electrical outlets, internet connection and
necessary furniture. The press conference room and
work room for the press will have a reception and catering space.- Mixed area: An area will be provided to allow media representatives
to speak and/or interview the players, on the
runway or on the runway to the changing rooms and/or from the changing rooms and the exit from the installation. Three areas will be reserved: one for TV, one for radio and one for written press. This area must be separated and not accessible to viewers and will have controlled access and different from that of athletes.- Reserved parking for media area:A reserved parking area for media will be provided, with differentiated entry and sufficient space for the vans of mobile TV and radio.18. SPACES FOR THE SPECTATORS spaces for the spectators will allow you to see the sports competitions that take place and will have the necessary auxiliary spaces such as: lobby/s access with area and information posters, access control, lockers, bar – cafeteria, toilets, cloakroom, etc. The spectator spaces shall be designed and constructed in such a way that they are accessible to persons with disabilities in a non-discriminatory, independent and safe manner, places for persons with reduced mobility shall be reserved (1 for wheelchair users per 100 places or fraction) and shall comply with national, regional and local regulations for that purpose. The spaces intended for spectators shall comply with the requirements of the Technical Building Code (CTE) and other current regulations, in particular that of public performances, accessibility and fires. Also these spaces will meet the requirements of the NIDE standard “Rooms and Pavilions”.The sports facilities where high-level sports competitions are to be held must have independent access for players and referees other than public ones, so that they cannot
come into direct
contact with the público.En competitions of the Real Federación Española de Fútbol (see below)
The number of spectators to be predicted depends on the level and character of the event deportivo.Las sports
facilities, where high-level competitions are held and/or when the nature of the event can be foreseen displacements of spectators that may cause dangerous accumulation of them, will have the graderais divided into sectors conveniently separated by security reasons, so that the different groups of followers are separated. The separation elements shall comply with the standard UNE-EN 13200-3 “Separation elements. Requirements.” The capacity of each sector shall not exceed 2,000 spectators and a larger sector may be divided into sub-sectors with a capacity not greater than that indicated. Each sector or subsector shall have at least 2 outputs. Each sector or subsector intended for spectators must be equipped with toilets and refreshment and rest areas for spectators in the sector, as well as separate exit routes, which must be easily identifiable and
marked with evacuation signals n.La A gallery of authorities and personalities will be in a central position, close to the playing field and in front of the players' banks and will be close to the hospitality room. The area must not be accessible to the public. In high-level competitions you will have a pre-palco and will be suitable for at least 50 personas.Tribunas Participants: A sufficient number of places
will be reserved in a special tribune for the members of the teams and organisations participating in the sports event that are not disputing the meeting. In
competitions of the Liga Nacional de Fútbol Sala the following minimum number of seats is required:
• Minimum capacity of 2,000 spectators sitting in 1st Division and 1,000 spectators sitting in 2nd Division. 15% of the capacity may be localities of pie.Para populations of less
than 50,000 inhabitants, the minimum capacity will be 1,500 spectators in 1st Division and 700 in 2nd Division.• In 1st Division it is
convenient to have stands on the two sides of the field with a capacity of at least 700 spectators each. In populations with fewer than 50,000 inhabitants the minimum capacity will be 500 espectadores.No,
but in sports facilities where high-level national competitions are to be held, if required by the authorities for the prevention of violence in sport, numbered localities and seats for
all espectadores.En high-level international competitions require a minimum capacity of 8,000 seated spectators and 12,000 seated spectators for semi-finals. 19 AVAILABILITY OF INDOOR FOOTBALL SPORTS FACILITIES WILL BE DESIGNED AND BUILT TO BE ACCESSIBLE TO PERSONS WITH DISABILITIES, ON A NON-DISCRIMINATORY, INDEPENDENT AND SAFE BASIS. They will have an external
itinerary accessible to the facility and itineraries accessible to the main track, the auxiliary sports spaces, (Changing rooms, nursing, etc.) and the spaces for spectators. The aforementioned sports, ancillary and spectator spaces shall be accessible, meeting the accessibility criteria specified in the NIDE standard “Halls and Pavilions” as well as the national, regional and local regulations for this purpose. It is recommended that they comply with the requirements of the UNE Accessibility Standards. 20. BASIC BIBLIOGRAPHY - Funtsal Game Rules 2012/2013, FIFA.- General Regulation 2012. Real Federación Española de Fútbol.- Rules of Futsal game for the total blind (B1) 2011/2012. Spanish Federation of
Sports for
the Blind.- Rules of Futsal Game for the Visually Impaired (B2)
2007/2008. Spanish Federation of Sports for the Blind.- Futsal
Game Rules 2009/2013, categories B1 and B2/B3. International Federation of Sports for the Blind.- Rules governing competitions.
National Futsal League, Season 2012-2013.- FIFA Quality Program for Balloons - Football Stadiums Technical Recommendations and Requirements. 11 Futsal and beach
soccer. 5th Edition 2011- UNE-EN standards of “Surfaces and Sports Equipment”- UNE-EN standards of “Lighting of sports facilities”- UNE-EN standards
of “Installations for spectators in sports facilities”- UNE standards of “Accessibility”